No student devices needed. Know more
30 questions
DIVISION 6
Wood And Plastics
Metals
Finishes
Thermal and Moisture
Protection
What is the purpose of “close boarded hoarding”?
To prevent the pavement from becoming dirty.
To prevent break-in from burglary, theft or pilferage.
To prevent accidents due to falling materials.
To provide support for shoring, scaffolding, and workers.
The installation of mechanical, electrical, and plumbing components that will not be exposed to view in the finished building.
Firestopping
Pre-entry
Roughing-in
Utility installation
DIVISION 11
Equipment
Specialties
Furnishings
Doors and Windows
Which kind of sprinkler system through which water flow is controlled by a valve operated by fire-detection devices more sensitive than those in the sprinkler heads. This type of sprinkler system is used when an accidental discharge could damage valuable materials.
Deluge system
Deluge system
Fusible link system
Preaction system
An open metal framework for supporting insulated electrical conductors.
Busway
Cable tray
Conduit
Duct
DIVISION 4
Concrete
Masonry
Metals
Wood and Plastics
What is the minimum fire resistive rating for a firewall under BP 220?
1 hour
2 hour
3 hour
4 hour
A continuous path of travel from any point in a building to the outside at ground level.
Area of refuge
Exit access
Fire escape
Means of egress
Division 15
Special Construction
Conveying Systems
Mechanical
Electrical
This is the term that refers to a component or mastic installed in an opening through a floor or wall to retard the passage of fire.
Sleeve
Firestopping
Safing
Fireproofing
A steel or plastic tube through which electrical wiring is run.
Chase
Conduit
Piping
Raceway
DIVISION 8
Doors and Windows
Wood And Plastics
Specialties
Furnishings
A louver shaped so as to distribute air about a room.
Damper
Diffuser
Plenum
Grille
This type of fireproofing is usually applied on structural steel members, mostly in a thick layer. This is also cheaper as compared to other options, but is very crude and aesthetically unpleasant. Moreover, if the environment is corrosive in nature, then this option is not advisable, as there is the possibility of water seeping due of its porous nature, and thus difficult to monitor for corrosion. What is this type of fireproofing?
Ablative
Endothermic
Perlitic
Vermiculite
DIVISION 13
Special Construction
Mechanical
Electrical
Conveying Systems
These materials usually have a large concentration of organic matter that is reduced by fire to ashes. In the case of silicone, organic rubber surrounds very finely divided silica dust. When the organic rubber is exposed to fire it burns to ash and leaves behind the silica dust with which the product started. In this characteristic, silicone is described as
Ablative
Endothermic
Intumescent
Perlitic
During a fire test, materials like gypsum wallboards or concrete walls are sacrificial and become "spent" over time while exposed to fire. Given sufficient time under fire or heat conditions, these products char away, crumble, and disappear. The idea is to put enough of this material in the way of the fire that a level of fire-resistance rating can be maintained. Concrete and gypsum materials are described as
Ablative
Endothermic
Intumescent
Vermiculite
Division 16
Special Construction
Electrical
Equipment
Finishes
These materials have substances that swell as a result of heat exposure thus increasing in volume and decreasing in density. In passive fire protection systems, these materials are used in a form of coating or mastic that expands to form a stable, insulating char when exposed to fire. These materials are said to be
Ablative
Endothermic
Intumescent
Perlitic
Which type of mechanical ventilation system causes the lowering of air pressure inside the house such that outdoor air is drawn in?
Balanced system
Evaporative cooling system
Exhaust-only system
Convection system
Division 5
Metals
Wood and Plastics
Masonry
Concrete
Firestop components include, among others, the following materials except one.
Intumescents
Cementitious mortars
Batts
Wrapped mineral fibers
Which of the following speaks true of the efficiency relationship between natural lighting and artificial (measured in terms of “cool white fluorescent” or CWF) lighting?
Artificial lighting is as efficient as natural lighting.
Artificial lighting is about half as efficient as natural lighting.
Artificial lighting is about twice as efficient as natural lighting
Artificial lighting is just about 20% as efficient as natural lighting.
Division 2
Concrete
Masonry
Site Construction
General Specifications
. Once occupied, units in medium- and high-rise residential buildings are eventually fitted out according to a unit owner’s preference. Which fit-out activity presents the least possible changes, if none at all?
Ceiling work
Electrical works
Plumbing
Flooring
A vertical panel of non-combustible or fire resistive material attached to and extending below the bottom chord of the roof trusses, to divide the underside of the roof into separate compartments so that heat and smoke will be directed upwards to a roof vent.
Cavity wall
Curtain board
Drywall
Fireblock
Division 12
Furnishings
Finishes
Equipment
Specialties
This term refers to the fire-resistant material inserted into a space between a curtain wall and a spandrel beam or column, to retard the passage of fire through the space.
Firestopping
Sleeve
Safing
Penetrant
The space between the ceiling of a room & the structural floor above, used as passage for ductwork, piping, & wiring.
Access flooring
Crawl space
Plenum
Substructure
Explore all questions with a free account