Mr. Manny Pacquiao has a new plans of his Mansion in Gen. Santos City. He needs to obtain a building permit, he is the owner of the lot. he must file all the necessary forms, together with accomplished application forms, the following shall be submitted to the OBO, except. (nbc, sec 302 - 2A)
Contract of Lease, or Deed of Absolute Sale
Certited true copy of OCT/TCT, on, file with the Registry of deeds
Tax declaration
Current Real Property tax receipt
The OBO inspector found out that the site of Mr. Manny Pacquiao had some Unauthorized change, modification or alteration during construction in the duly submitted plans and specifications on which the building permit is based. What will be the violation and fines? (nbc, sec 212)
No violation, Because he is a Senator of Rep. of the Philippines.
Less grave violation = 8,000 pesos
Light violation = 5,000pesos
Grave violation = 10,000 pesos
The second floor slab was designed to resist fire for two (2) hours, as per NBCP rule VI. What is the minimum overall thickness of slab and cover to reinforcement of the said slab? (nbc, sec 603)
150mm overall; 30mm concrete cover
100mm overall; 15mm concrete cover
120mm overall; 25mm concrete cover
125mm overall; 20mm concrete cover
This shall be issued by the building official within 30 days if after final inspection and submittal of a certificate of completion; it is found that the building/structure complies with the provisions of the NBCP. (nbc, sec 309)
technical transfer certificate
Certificate of completion
Certificate of occupancy
Birth certificate
PD 1096: Width and Height of doors will be not less than ___ mm in width, not less than ___ m in height, opening will be 90 degrees and exit way clear width not less than 700mm? (sec. 1207-3c)
900, 2.10
900, 2.00
800, 2.00
800, 2.10
If arcaded bldg, no chaflan required notwithstanding the width of public street, less than ___ m? (sec 1008-3)
3.60
4.00
2.40
1.80
Spacing of rows of seats from back to back - not less than mm(standard seating) (sec. 1207 - 13a)
840mm
850mm
860mm
900mm
If only 2 exits required, shall be placed distance apart not less than ___ of the perimeter area. (sec. 1207 - 2c)
1/3
1/4
1/5
1/2
Hoistway pits shall be of such depth that when the car rests on the fully compressed buffers, a clearance of not less than ___ remains between the underside of the car and the bottom of the pit? (NBC rule XIl sec. 1302)
300mm
500mm
400mm
600mm
Foundations - not less than ___ below the grade, may encroach ___ into public sidewalk areas. (sec. 1002 - 3)
600cm, 500cm
0.60m, 500mm
0.50m, 600mm
2.40m, 300mm
Footings must be at least ___ below grade along national roads, may project not more than ___ beyond Property line. (sec. 1002 - 1)
600mm, 500mm
2.50m, 300mm
2.30, 400mm
2.40, 300mm
What type of construction is for steel, iron concrete construction with fire resistant materials 1 hr. fire resistive rating. (sec. 401 - 2)
Type V
Type II
Type IV
Type III
Vertical Clearance of awning (undermost surface of the awning or GL) - not less than ___ m? (sec. 1006 - 2)
3.00m
2.70m
2.40m
2.80m
The width of a stair way if the occupant load of less than 50 shall not be less than ___ m? (sec. 1207 - 5a)
0.90m
1.00m
0.80m
1.10m
The slope of an exit passageway will have a maximum slope of? (sec. 1207 - 10b)
1/8
1/15
1/10
1/12
The rating in which a material can withstand fire? (sec. 601)
Fire Resistive Time Period Rating
Fire Protective Rating
Fire Resistive Rating
Fire Respective Rating
The number of exits for Mezzanine with 185 sq.m area or more than 18m in dimension will be exits? (sec. 1207 - 2a)
1
2
3
4
The minimum row space with backrest will be? (sec. 1207 - 14-c-i)
700mm
750mm
850mm
800mm
The maximum rise and minimum run of the stairs will be? (sec. 1207 - 5b)
250mm, 200mm
200mm, 250mm
200mm, 300mm
170mm, 250mm
The general provision of PD 1096 or the National Building Code of the Philippines are? (sec. 104)
Maintain building in safe, sanitary and good working conditions
Adequate environmental safeguards
Safe construction
All of the above
On the first sheet of the standard title block prescribed by the OBO contains a space for division/ section action, what office is stated on the fifth space block from the upper right? (nbc, sec 302, Fig 3-1)
Line & Grade
Architectural
Civil/Structural
Mechanical
The door that shall swing in the direction of exit travel when serving any hazardous areas or when serving an occupant load of fifty (50) or more. (sec. 1207 - 3a)
Exit Door
Double Acting Door
Emergency Door
Panic Door
The distance between 2 landings in stairs will be a maximum of? (sec. 1207 - 5g)
3.00m
3.50m
3.60m
2.70m
The building permit will be null or void if the construction didn't commenced the work in a period of? (sec. 305)
6 months
12 months
120 days
3 months
Every landing shall have a dimension measured in the direction of travel equal to the width of the stairway. Such dimension need not exceed ___ meters when the stairs has a straight run.? (sec. 1207 - 5e)
1.50m
1.20m
1.40m
1.30m
Service drop of conductors crossing the public road shall have a clearance of not less than ___ from the crown of the street over which it passes; and shall have a minimum clearance of ___ above ground at its point of attachment to the building or pedestal. (sec. 1301-5d)
5.00m, 2.80m
6.00m, 3.50m
5.50cm, 3.00cm
5500mm, 3000mm
Side aisle width will be a minimum of? (sec. 1207-12a)
1.00m
1.10m
1.20m
1.30m
What is the minimum distance required between roof eaves and rear/side property lines?
500mm
750mm
1000mm
1500mm
Firewalls are not allowed for R1 developments. However, an abutment of up to ___ in height is allowed, provided that above 1.50m, the abutment is made of perforated concrete blocks.
2.00m
2.70m
3.00m
3.20m
For a sloping lot with a 4.00m difference between the highest and lowest points of the lot, where will the established grade line be for building height determination?
The lowest point of the lot
The highest point of the lot
The average between the two points
None of the above
What is the minimum parking slot size for an articulated truck?
2.50m x 5.00m
3.00 x 9.00m
3.60 x 18.00m
3.60 x 22.00m
If you add the ISA and the USA, what will you get?
TOSL
PSO
MACA
AMBF
If you subtract the ISA from the construction area, what will you get?
TOSL
PSO
USA
BHL
What is the minimum area for habitable rooms, according to the National Building Code?
1.20 sqm
3.00 sqm
6.00 sqm
12 sqm
What is the minimum air space provision per person for habitable rooms?
3.00 cubic meters
12.00 cubic meters
14 cubic meters
18 cubic meters
For forest areas, the NBC requires at least _____ of easement for each side of the waterway.
3.00m
10.00m
20.00m
40.00m
Rowhouses 1-3 storeys high fall under which zoning classification?
R-2
R-3
GI
C-1
What is the minimum size of a classroom for 30 students and 1 teacher, according to the occupant load factors in Rule 12 of the Building Code?
54.00 sqm
55.80 sqm
138.00 sqm
142.60 sqm
What is the maximum travel distance to an exit if the building has an automatic fire extinguishing system?
30 meters
45 meters
60 meters
75 meters
Maximum width of a door leaf
There is no maximum width for a door leaf
800mm
900mm
1200mm