micropipette
transfer pipette
pipette pump
serological pipette
Mason is working in a chemistry lab. He is using a micropipettor to prepare a solution. If he pushes to the second stop to fill the micropipettor, he will get ____________
the correct amount of solution
too much solution
too little solution
either too much or too little solution
Henry, Maya, and Rohan are working in a lab and are having a friendly competition to see who can select the appropriate size of micropipettes for their experiment the fastest. Which sizes should they choose to measure 146 uL (microliters) ______________?
A PTP (plastic transfer pipette)
A 5 - 50 uL micropipettor
A 2 - 200 uL micropipettor
A graduated cylinder
Elijah, Jackson, and Evelyn are in a lab, and they need to accurately fill a micropipettor. What should they do?
Add a tip and push the button to the first stop.
Add a tip and push the button to the second stop
Turn the white wheel upward
Push the eject button
Scarlett is working in a lab and needs to convert mL to uL for her experiment. If she has 1 mL of a solution, how many uL does she have?
1
10
100
1000
Nora, Luna, and Benjamin are in a science lab. They come across a piece of equipment. Nora thinks it's used to
measure & transfer large volumes
measure & transfer small volumes
spin chemicals/tubes
sterilize equipment
Anika is using a P20 micropipette in her biology lab to measure a liquid sample. The P20 micropipette measures volumes from 2-20 microliters. Which of the following volumes could she measure with this micropipette?
0.98 ul
9.8 ul
98 ul
980 ml
During a lab, you need to transfer 4.5 mL of a solution from a 150 mL flask to a 15 mL conical tube. Which of the following would be the best to use?
25 mL beaker
5 mL serological pipette
50 mL graduated cylinder
P10 micropipette
Imagine Michael, Hannah, and Nora are in a science lab. They need to transfer 1-2 ml of liquid for their experiment. Which tool should they use?
Graduated Cylinder
transfer pipette
micropipette
serological pipette
A _________has a cotton plug at the top end to slow water down. In case you overfill this will give you enough time to react and stop/reverse what you are doing before the water enters the barrel of the pipette pump.
Pasteur pipette
Serological pipette
Tip
Transfer pipette
Imagine you are in a science lab with Daniel, Abigail, and Ava. You see a piece of equipment and Daniel says, 'We should use this with ___.' What is he referring to?
Pasteur pipette
Serological pipette
Tip
Transfer pipette
pipette aid
You should NEVER rotate the volume adjuster on a micropipette beyond the upper and lower limit
true
false
Never invert or lay the micropipette down with a filled tip; fluid can flow back into the barrel and contaminate it for future use.
true
false
Letting the plunger of the micropipette snap back after withdrawing or expelling fluid won't damage the piston.
true
false
You must immerse the barrel of the micropipette in fluid, when taking in liquid
true
false
If you place the tip of a micropipette over a flame to sterilize it, it won't melt.
true
false
Sophia and Benjamin are having a debate. Sophia says that you should always change out the micropipette tip when changing reagents, but Benjamin isn't so sure. Who is correct?
Sophia (Always change the micropipette tip)
Benjamin (No need to change the micropipette tip)
Micropipettes are very accurate tools of measurement, but they are only as accurate as the person using it.
true
false
When expelling a liquid from a micropipette tip, it should be done up against the wall of the receiving container to allow the capillary action to draw out the liquid entirely.
true
false
Select the size of micropipettes we use in this lab.
10-50ml
.5-10ul
2-20ul
20-200ul
100-1000ml
Explore all questions with a free account